• Title of article

    Radiation hardness studies for the X-ray Solar Monitor (XSM) onboard the ESA SMART-1 mission

  • Author/Authors

    Laukkanen، نويسنده , , J. and Lنmsن، نويسنده , , V. and Salminen، نويسنده , , A. and Huovelin، نويسنده , , J. and Andersson، نويسنده , , H. and Alha، نويسنده , , L. and Hنmنlنinen، نويسنده , , K. and Nenonen، نويسنده , , S. and Sipilن، نويسنده , , H. and Tillander، نويسنده , , M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    20
  • From page
    496
  • To page
    515
  • Abstract
    The X-ray detection performance of the X-ray Solar Monitor (XSM, onboard the ESA SMART-1 satellite) Si pin-detector was studied after exposure to several types of radiation typical of the space environment (i.e. protons, electrons and γ -radiation). The detector withstands the tested radiation types at the expected mission dose levels. Hence, the XSM is expected to sustain an adequate performance level throughout the SMART-1 mission, needed to accomplish the planned scientific program. Also, first results of mission operations are presented.
  • Keywords
    Si pin-detector , Particle radiation dose , Particle radiation hardness , Particle radiation damage , X-ray detector