Title of article :
Lessons learned from the BaBar Silicon Vertex Tracker
Author/Authors :
Calderini، نويسنده , , Giovanni، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
6
From page :
67
To page :
72
Abstract :
The Silicon Vertex Tracker (SVT) of the BABAR experiment at the PEP-II asymmetric B factory consists of a five-layer double sided, AC coupled silicon microstrip detector. It represents a key element to measure with precision the decay position of B mesons, satisfying the severe constraints imposed by the accelerator design, in terms of geometry of the interaction region and conditions of operation. In the following paper, a critical review of the SVT general design and performance is made, with special attention to those details of the design and the assembly procedure that are considered a source of possible problems given the experience accumulated during the construction, the commissioning and the first 5 years of operation.
Keywords :
Silicon detectors , Strip detectors , Tracking , Radiation damage
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2005
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2203264
Link To Document :
بازگشت