Title of article :
A compact neutron detector using scintillators with wavelength shifting fibers by backside readout method
Author/Authors :
Katagiri، نويسنده , , M and Matsubayashi، نويسنده , , M and Sakasai، نويسنده , , K and Nakamura، نويسنده , , T and Ebine، نويسنده , , M and Birumachi، نويسنده , , A and Rhodes، نويسنده , , N، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
4
From page :
313
To page :
316
Abstract :
A compact neutron-imaging detector was developed by composition of backside readout method and WLS fibers bended at the right angle. The position resolutions were 0.6 and 0.7 mm for X- and Y-axis, respectively, which were almost as same as that of crossed-fiber readout method. Consequently, a neutron-imaging detector module that has small dead neutron detection area, for example, 15% of the whole front area can be manufactured.
Keywords :
scintillator , Imaging detector , Neutron , Backside readout , WLS fiber , Photon counting
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2004
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2203698
Link To Document :
بازگشت