Title of article
Radiation hardness on very front-end for SPD
Author/Authors
Cano، نويسنده , , Xavier and Graciani، نويسنده , , Ricardo and Gascَn، نويسنده , , José David and Garrido-Lَpez، نويسنده , , Lluيs and Bota، نويسنده , , Sebastià and Herms، نويسنده , , Atilà and Comerma، نويسنده , , Albert and Riera، نويسنده , , Jordi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
11
From page
458
To page
468
Abstract
The calorimeter front-end electronics of the LHCb experiment will be located in a region, which is not protected from radiation. Therefore, all the electronics must be qualified to stand some defined radiation levels. The procedure, measurements and results of an irradiation test for every component of the very front-end SPD detector, which is part of the LHCb calorimeter are presented here. All the tested components, except a custom made ASIC, are commercially available.
Keywords
Triple Voting Register , Large Hadron Collider LHC , Radiation hardness , Single Event Effects , Scintillator Pad Detector SPD
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2005
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2204113
Link To Document