Title of article :
Radiation shielding for underground low-background experiments
Author/Authors :
Stewart ، نويسنده , , D.Y. and Harrison، نويسنده , , P.F. and Morgan، نويسنده , , B. and Ramachers، نويسنده , , Y.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
12
From page :
651
To page :
662
Abstract :
The design task of creating an efficient radiation shield for the new COBRA double-beta decay experiment led to a comprehensive study of commercially available shielding materials. The aim was to find the most efficient combination of materials under the constraints of an extreme low-background experiment operating in a typical underground laboratory. All existing shield configurations for this type of experiment have been found to perform sub-optimally in comparison to the class of multilayered configurations proposed in this study. The method used here to create a specific shield configuration should yield a close to optimal result when applied to any experiment utilising a radiation shield. In particular, the survey of single material response to a given radiation source turns out to give a guideline for the construction of efficient multilayer shields.
Keywords :
Radiation shielding , Dark matter , Monte-Carlo , Double-beta decay , Low background