Title of article :
AC magnetic field measurement of CSNS/RCS quadrupole prototype
Author/Authors :
Zhou، نويسنده , , J.X. and Li، نويسنده , , L. and Yin، نويسنده , , B.G and Deng، نويسنده , , C.D. and Kang، نويسنده , , W. and Fu، نويسنده , , S.N.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
4
From page :
72
To page :
75
Abstract :
Rapid Cycling Synchrotron (RCS) is a key component of China Spallation Neutron Source (CSNS). It accumulates and accelerates protons to design energy of 1.6 GeV at the repetition rate of 25 Hz, and extracts high energy beam to the target. Performance of a high energy and high intensity accelerator depends crucially on the field quality of magnets employing to guide and focus a circulating beam. To study the properties of the AC magnet, a harmonic coil measurement system has been developed. To get the error of high order harmonics and the error of field at basic frequency, which was excited by harmonic currents, a series of harmonic coefficients of field is used to express the varieties of dynamic fields in space and time simultaneously. The measurement system has been tested in IHEP, and the property of the quadrupole prototype has been measured. The measurement system, principle, methods and primary results are illustrated in this paper.
Keywords :
CSNS/RCS quadrupole magnet , AC magnetic field measurement , Harmonic coil
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2011
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2204873
Link To Document :
بازگشت