• Title of article

    Investigation and development of microchannel plate phototubes

  • Author/Authors

    Barnyakov، نويسنده , , A.Yu. and Barnyakov، نويسنده , , M.Yu. and Barutkin، نويسنده , , V.V. and Bobrovnikov، نويسنده , , V.S. and Buzykaev، نويسنده , , A.R. and Gulevich، نويسنده , , V.V. and Kononov، نويسنده , , S.A. and Kravchenko، نويسنده , , E.A. and Onuchin، نويسنده , , A.P. and Tsigankov، نويسنده , , D.A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    4
  • From page
    404
  • To page
    407
  • Abstract
    The development of photomultiplier tubes (PMTs) with microchannel plates (MCPs) in Novosibirsk began 10 years ago. PMT based on MCP is compact, has a high time resolution and can work in a strong magnetic field. Eighty such PMTs have been working in ASHIPH counters of the KEDR detector since 2003. Now we are focusing on the MCP PMT lifetime improvement. It was shown that the photocathode lifetime cannot be expressed unambiguously in units of the collected anode charge. Two new models of PMTs were developed: PMT with the photocathode protective layer and PMT with three MCPs. The comparison of the photocathode aging of both new and one old models has been done.
  • Keywords
    MCP PMT , Photocathode lifetime , Aging effect , Cherenkov counters
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2007
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2205172