• Title of article

    Correction of a neutron diffraction peak shift due to a partial immersion of a gauge volume in an unstressed sample

  • Author/Authors

    Taran، نويسنده , , Yu.V. and Balagurov، نويسنده , , A.M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    6
  • From page
    19
  • To page
    24
  • Abstract
    There exists an effect of variation of peak positions measured by neutron diffraction if the gauge volume is only partially immersed in a sample. In literature, this diffraction peak shift is known as pseudostrain or surface effect. The correction of the peak position on the pseudostrain effects may be made by analytical calculation or Monte Carlo simulation. We have developed a reductive analytical approach to account for the pseudostrain effect in a thin-walled sample using a concept of pseudo-time introduced by Creek et al. [4] for time-of-flight (TOF) neutron diffraction experiments. The approach was verified on the diffraction experimental data obtained by two groups of researchers [1,2] with a stress-free nickel powder sample. Our corrections of the pseudostrain effects in these experiments are very satisfactory.
  • Keywords
    Surface effect , Pseudostrain , Thin-walled sample , Gauge volume , Neutron diffraction , Residual stress , strain
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2012
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2205987