Title of article :
Estimation of angular distribution of neutron dose using time-of-flight for system at 110 MeV
Author/Authors :
Nandy، نويسنده , , Maitreyee and Sunil، نويسنده , , C. K. Maiti، نويسنده , , Moumita and Palit، نويسنده , , R. R. Sarkar، نويسنده , , P.K.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
9
From page :
380
To page :
388
Abstract :
We have reported measured angular and energy distributions of neutron dose from 110 MeV 19F projectiles bombarding a thick aluminum target. The measurements are carried out with BC501 liquid scintillator detector using the time-of-flight technique. We have measured neutron energy distributions at 0 ∘ , 30 ∘ , 60 ∘ , 90 ∘ , and 120 ∘ and converted them to dose distributions using the ICRP recommended fluence to ambient dose equivalent and absorbed dose conversion coefficients. Similar conversions to ambient dose equivalent are done for theoretically estimated distributions from the nuclear reaction model code EMPIRE-2.18. The experimental results are compared with calculated ambient dose equivalent from different empirical formulations proposed by earlier workers. Based on the comparison, we have attempted modifications of the parameters in these empirical expressions.
Keywords :
Neutron dose , heavy ion , BC501 , Time-of-flight , Thick target , empire
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2007
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2206174
Link To Document :