• Title of article

    Prompt gamma-ray analysis of chlorine in superpozz cement concrete

  • Author/Authors

    Naqvi، نويسنده , , A.A. and Kalakada، نويسنده , , Zameer and Al-Matouq، نويسنده , , Faris A. and Maslehuddin، نويسنده , , M. and Al-Amoudi، نويسنده , , O.S.B. and ur-Rehman، نويسنده , , Khateeb، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    7
  • From page
    67
  • To page
    73
  • Abstract
    The chlorine concentration in Superpozz (SPZ) cement concrete was analyzed using a newly designed prompt gamma-ray neutron activation (PGNAA) setup utilizing a portable neutron generator. The setup, which mainly consists of a neutron source along with its moderator placed side by side with a shielded gamma-ray detector, allows determining chloride concentration in a concrete structure from one side. The setup has been tested through chlorine detection in chloride-contaminated Superpozz (SPZ) cement concrete specimens using 6.11 and 2.86±3.10 MeV chlorine prompt gamma-rays. The optimum 0.032±0.012 wt% value of Minimum Detectable Concentration (MDC) of chlorine in SPZ cement concrete measured in this study shows a successful application of a portable neutron generator in chloride analysis of concrete structure for corrosion studies.
  • Keywords
    Chloride Analysis in Superpozz concrete , Portable Neutron Generator , Concrete Corrosion Studies , PGNAA portable design for field measurements , Prompt Gamma Ray Analysis
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2012
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2206444