Title of article :
The measurements of laser beam transmission through exposed/etched CR-39 and CN-85 detectors
Author/Authors :
Salman، نويسنده , , Thaer M. and Subber، نويسنده , , Abdul R.H. and AL-Ahmad، نويسنده , , Alaa Y.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
4
From page :
251
To page :
254
Abstract :
In the present trackology work, CR-39 and CN-85, solid state nuclear track detectors (SSNTDs) were irradiated with alpha particles and gamma rays for different irradiation times. These detector foils were chemically etched by NaOH solution with specified normality. The intensity of transmitted laser light (λ=650 nm) through irradiated and etched detectors was measured using a photodiode. The method appeared as a good technique for dose measuring but it is extremely dependent on the etching time, the type of incident particles and the type of the detector. It is found that the response of CN-85 detector looks faster and better than CR-39 detector.
Keywords :
Trackology , Laser light , Transmittance , SSNTDs , Optical properties