Title of article :
Pixellated TlBr detectors with the depth sensing technique
Author/Authors :
Hitomi، نويسنده , , Keitaro and Onodera، نويسنده , , Toshiyuki and Shoji، نويسنده , , Tadayoshi and He، نويسنده , , Zhong، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
4
From page :
235
To page :
238
Abstract :
The depth sensing technique has been introduced to a 1.8 mm thick pixellated thallium bromide (TlBr) detector in order to enhance the performance of the device. Significant improvement of the energy resolution has been achieved with the device. An energy resolution of 2% FWHM at 662 keV was recorded with the device after the depth correction and rejection.
Keywords :
Thallium bromide , Semiconductor detectors , Position-sensitive detectors
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2007
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2206656
Link To Document :
بازگشت