Title of article
Radiation shielding considerations against gas bremsstrahlung for the BioXAS beamlines at the Canadian Light Source
Author/Authors
Asai ، نويسنده , , Juhachi and Coulthard، نويسنده , , Ian، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
10
From page
492
To page
501
Abstract
The BioXAS beamlines consist of an undulator beamline followed by two wiggler beamlines sharing the same insertion device. To contain gas bremsstrahlung in the primary optical enclosure (POE), three tungsten blocks are placed, one of which is common to all the three beamlines.
ation shielding study is carried out for primary and secondary gas bremsstrahlung of the BioXAS beamlines. Dose rates behind the back wall, side wall and the top of the roof are obtained by calculating energy depositions in a water phantom, which surrounds the POE. Discussion is made regarding the adequacy of radiation shielding for the BioXAS beamlines, which will be built in the near future at the Canadian Light Source.
Keywords
Gas bremsstrahlung , Monte Carlo , Insertion device , Beam stop , POE , Dose rate
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2010
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2206818
Link To Document