Title of article
Pulse requirements for field integral measurements in pulsed wire method
Author/Authors
Tripathi، نويسنده , , Sumit and Mishra، نويسنده , , G. and Kumar، نويسنده , , Vinit and Chouksey، نويسنده , , Sanjay and Kumar، نويسنده , , Ravi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
6
From page
121
To page
126
Abstract
The pulse requirements in pulsed wire measurements are verified for undulators with and without end field corrections. For a perfect undulator, the second field integral is uniform along the length of the undulator and the required pulse size is calculated by the distance of the sensor divided by the wave velocity. The undulator without end field correction or with improper end field configuration requires longer pulse sizes than the shimmed undulator for both first and second field integral results.
Keywords
Free-electron laser , Undulator , Pulsed wire method , Magnetic field measurement
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2011
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2208135
Link To Document