• Title of article

    Linear polarization sensitivity of SeGA detectors

  • Author/Authors

    Miller، نويسنده , , D. K. Chester، نويسنده , , A. and Moeller، نويسنده , , V. I. Starosta، نويسنده , , K. and Vaman، نويسنده , , Kizhake C. and Weisshaar، نويسنده , , D.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    6
  • From page
    713
  • To page
    718
  • Abstract
    Parity is a key observable in nuclear spectroscopy. Linear polarization measurements of γ -rays are a probe to access the parities of energy levels. Utilizing the segmentation of detectors in the Segmented Germanium Array (SeGA) at the NSCL and analyzing the positions of interaction therein allows the detectors to be used as Compton polarimeters. Unlike other segmented detectors, SeGA detectors are irradiated from the side to utilize the transversal segmentation for better Doppler corrections. Sensitivity in such an orientation has previously been untested. A linear polarization sensitivity Q ≈ 0.14 has been measured in the 350-keV energy range for SeGA detectors using α – γ correlations from a Cf 249 source.
  • Keywords
    Segmented germanium detectors , Polarization sensitivity , Gamma-ray Compton polarimeters
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2007
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number