• Title of article

    Development of gaseous PMT with micropattern gas detector

  • Author/Authors

    Tokanai، نويسنده , , Fuyuki and Sumiyoshi، نويسنده , , Takayuki and Sugiyama، نويسنده , , Hiroyuki and Okada، نويسنده , , Teruyuki and Ohishi، نويسنده , , Noboru and Ohmura، نويسنده , , Takayuki and Sakurai، نويسنده , , Hirohisa and Gunji، نويسنده , , Shuichi، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    5
  • From page
    164
  • To page
    168
  • Abstract
    We have developed gaseous photomultiplier tubes (PMTs) with a bialkali photocathode, combined with micropattern gas detectors (MPGDs) such as a glass capillary plate (CP), a gas electron multiplier (GEM) and a Micromegas detector. Gaseous PMTs with two different gas mixtures of Ar (90%)+CH4 (10%) and Ne (90%)+CF4 (10%) were investigated at a gas pressure of 1 atm. Quantum efficiencies of up to 12% were obtained for both neon and argon gas mixtures. A new glass CP made of Pyrex glass has been developed for a hole-type MPGD. The glass is well-suited for high-level cleanliness and reaction conditions required for the production of bialkali photocathodes. A gain of up to 1.5×104 and an energy resolution of 23% were obtained for 5.9 keV X-rays. This latest result and the basic performance of the gaseous PMTs are described.
  • Keywords
    Gaseous PMT , Micropattern Gas Detector , Glass capillary plate
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2009
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number