• Title of article

    Lifetime studies of the 19-channel hybrid photodiode for the CMS hadronic calorimeter

  • Author/Authors

    Cushman، نويسنده , , Priscilla and Sherwood، نويسنده , , Brian، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    9
  • From page
    250
  • To page
    258
  • Abstract
    A subset of the ∼1000 CMS hybrid photodiode tubes which passed through our quality assurance program was subjected to long term testing of their properties as a function of time. Over the course of several years, the tubes were operated under non-uniform illumination at rates up to 3.75 nW per pixel and for total integrated charges of up to 7 C at the anode. In situ measurements of quantum efficiency and gain, coupled with periodic photocathode uniformity scans, dark current and cross talk, provide information on expected time-dependent changes in the tube photosensitivity and some indication of possible failure modes.
  • Keywords
    CMS HCAL , HPD , Hadronic calorimeter , Hybrid photodiode
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2008
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2209227