Title of article :
Performance of a single photon counting microstrip detector for strip pitches down to 10 μm
Author/Authors :
Bergamaschi، نويسنده , , A. and Broennimann، نويسنده , , Ch. and Dinapoli، نويسنده , , R. and Eikenberry، نويسنده , , E. and Gozzo، نويسنده , , F. and Henrich، نويسنده , , B. and Kobas، نويسنده , , M. and Kraft، نويسنده , , P. and Patterson، نويسنده , , B. and Schmitt، نويسنده , , B.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
4
From page :
163
To page :
166
Abstract :
The MYTHEN detector is a one-dimensional microstrip detector with single photon counting readout optimized for time resolved powder diffraction experiments at the Swiss Light Source (SLS). The system has been successfully tested for many different synchrotron radiation applications including phase contrast and tomographic imaging, small angle scattering, diffraction and time resolved pump and probe experiments for X-ray energies down to 5 keV and counting rate up to 3 MHz. The frontend electronics is designed in order to be coupled to 50 μm pitch microstrip sensors but some interest in enhancing the spatial resolution is arising for imaging and powder diffraction experiments. structure with strip pitches in the range 10–50 μm has been tested and the gain and noise on the readout electronics have been measured for the different strip pitches, observing no large difference down to 25 μm. Moreover, the effect of the charge sharing between neighboring strips on the spatial resolution has been quantified by measuring the Point Spread Function (PSF) of the system for the different pitches.
Keywords :
Charge sharing , Photon counting , Silicon microstrip detector
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2008
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2209658
Link To Document :
بازگشت