Title of article :
Cross-talk suppressed multi-anode MCP-PMT
Author/Authors :
Inami، نويسنده , , K. and Mori، نويسنده , , T. and Matsumura، نويسنده , , T. and Kurimoto، نويسنده , , K. and Hasegawa، نويسنده , , S. and Suzuki، نويسنده , , Y. and Murase، نويسنده , , T. and Yurikusa، نويسنده , , Y. and Akatsu، نويسنده , , M. and Enari، نويسنده , , Y. and Hokuue، نويسنده , , T. and Tomita، نويسنده , , A. and Kishimoto، نويسنده , , N. and Ohshima، نويسنده , , T. and Ihara، نويسنده , , T. and Nishizawa، نويسنده , , H.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
7
From page :
247
To page :
253
Abstract :
We have developed a 4-channel multi-anode MCP-PMT, SL10, which exhibits good performance of the transit time spread, σ TTS ≃ 30 ps for single photons with a gain of ∼ 10 6 and a peak quantum efficiency of 20 % under a magnetic field of ⩽ 1.5 T . The cross-talk among anodes has been extensively studied. We have taken two measures to suppress it: one is to configure the SL10 to an effectively independent four small pieces of MCP-PMTʹs by segmenting an electrode of the second MCP-layer; the other is to use a constant-fraction discriminator. A remarkable improvement has been achieved.
Keywords :
MCP-PMT , TOP counter , Cross-talk
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2008
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2209833
Link To Document :
بازگشت