Title of article :
Performance of a low-pressure Micromegas-like gaseous detector
Author/Authors :
Nakhostin، نويسنده , , Mohammad، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
5
From page :
496
To page :
500
Abstract :
We studied the properties of low-pressure Micromegas detectors in which the length of the amplification gap was slightly increased to improve the attainable gas gain. Two detectors with amplification gaps of 200 and 400 μm were constructed and operated at gas pressures below 60 Torr. Large gas gains (104–105) and fast signals (100–200 ns duration) were observed and the possibility of obtaining an ion backflow as low as 10−4 was demonstrated. These properties, combined with the simple and robust structure of the detector which result from the increased length of amplification gap, make it an attractive choice for applications which benefit from low-pressure operation.
Keywords :
Micromegas , Low-pressure detector , Gas detectors
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2009
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2210611
Link To Document :