Title of article
Density, dielectric constant and PVT measurements of a gas condensate fluid
Author/Authors
May، نويسنده , , Eric F. and Edwards، نويسنده , , Terence J. and Mann، نويسنده , , Anthony G. and Manning، نويسنده , , David K.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
12
From page
297
To page
308
Abstract
Simultaneous measurements of the volume, dielectric constant and density have been made in both the vapor and liquid phases of a gas condensate fluid. The dielectric constant was measured with a microwave reentrant resonator, the density with a commercial vibrating tube densimeter and the volume with a PVT cell optimised for measurements on gas condensate fluids. Gas chromatography (GC) was used to determine the fluidʹs composition. Sample fluid in the microwave resonator, densimeter and PVT cell could be thoroughly mixed expediting equilibrium and preserving sample integrity. Measurements were made at approximately 308 and 318 K at 12.4 MPa, conditions representative of the well head. These data will allow the calibration of multiphase flow meters used in the production stream of this fluid. The data are compared with the predictions of a cubic equation of state to ascertain whether simple correlations can provide the accuracy necessary to calibrate multiphase flow meters.
Keywords
Gas condensates , dielectric constant , Density , Multiphase flow , Phase behaviour
Journal title
Journal of Petroleum Science and Engineering
Serial Year
2004
Journal title
Journal of Petroleum Science and Engineering
Record number
2215337
Link To Document