Title of article :
Centrifuge modeling of non-connected piled raft system
Author/Authors :
Rasouli، H. نويسنده MSc. Student, School of Civil Engineering, Iran University of Science and Technology, Tehran, Iran , , Saeedi Azizkandi، A. نويسنده he is currently a PhD degree student. , , Baziar، M.H. نويسنده professor of Civil Engineering at Iran University of Science and Technology. , , Modarresi، S. M. H. نويسنده , , Shahnazari، H. نويسنده Iran University of Science and Technology Shahnazari, H.
Pages :
10
From page :
114
To page :
123
Abstract :
In present research, 17 centrifuge tests have been conducted to study the effect of various parameters such as the number of piles, the distance between piles, gradation and thickness of the granular layer on the load-settlement behavior of a pile raft system. The results showed the importance of granular layer to reduce the settlement of non-connected pile raft system when the roles of piles are to reduce the settlement. In other words when the piles have major contribution on the bearing capacity of pile raft system, presence of a granular layer may increase the settlement.
Journal title :
International Journal of Civil Engineering(Transaction B: Geotechnical Engineering)
Serial Year :
2015
Journal title :
International Journal of Civil Engineering(Transaction B: Geotechnical Engineering)
Record number :
2218825
Link To Document :
بازگشت