• Title of article

    Simple model of electric submersible pump in gassy well

  • Author/Authors

    Zhou، نويسنده , , Desheng and Sachdeva، نويسنده , , Rajesh، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    10
  • From page
    204
  • To page
    213
  • Abstract
    Electric submersible pump (ESP) is a widely used artificial lift method for oil production. Free gas at the pump intake can degrade the ESP performance. Degradation can be in the form of reduced head, surging and gas locking. aper presents a new easy-to-use model intended for the field engineer. The modelʹs parameters are obtained by using linear multiple regression analysis on measured data. The model is not pump-specific as it uses dimensionless head and rate. In addition, a critical model and a simple equation are presented to predict the start of surging, which can cause pump instability and even gas lock. The study also gives the field engineer an idea of how the liquid-only affinity laws are impacted in multiphase flow conditions. ed with available models, the presented pump head degradation model and the critical model are both the best.
  • Keywords
    Electric submersible pump , head deterioration , multiphase pumping , Critical condition , affinity laws
  • Journal title
    Journal of Petroleum Science and Engineering
  • Serial Year
    2010
  • Journal title
    Journal of Petroleum Science and Engineering
  • Record number