Title of article :
Development and Validation of a New Capillary Electrophoresis Assay for Monitoring of Atenolol Photodegradation Product in Non-aqueous Solution
Author/Authors :
Hasanzadeh، Mohammad نويسنده Drug Applied Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz 51664, Iran Hasanzadeh, Mohammad , Shadjou، Nasrin نويسنده Department of Analytical Chemistry, Faculty of Science, Payame Noor University(PNU), P.O. Box 58168- 45164, Khoy, Iran , , Kazeman، Isa نويسنده Department of Chemistry, K. N. Toosi University of Technology (KNTU), P. O. Box 15875-4416, Tehran, Iran , , Jouyban، ABOLGHASEM نويسنده ,
Issue Information :
دوماهنامه با شماره پیاپی 0 سال 2014
Pages :
15
From page :
219
To page :
233
Abstract :
The characterization of atenolol photodegradation product was performed using capillary electrophoresis (CE) with ultraviolet diode array detector (UV-DAD). The optimum separation for this assay was achieved in < 7 min at 298 K with a fused-silica capillary column (57 cm length and 75 ?m I.D.) and a running buffer containing 60 mM acetate buffer at pH 5.3 dissolved in methanol/ethanol mixture (20:80% v/v). The samples were injected with applied voltage of 16.0 kV. It’s established that capillary electrophoresis method enables to detect atenolol photodegradation product. The suggested method has been used for the determination of the studied drug in human serum and the results were compared to the other reported methods
Journal title :
Analytical and Bioanalytical Electrochemistry
Serial Year :
2014
Journal title :
Analytical and Bioanalytical Electrochemistry
Record number :
2229995
Link To Document :
بازگشت