Title of article :
Reverse analysis of a spiral injector to find geometrical parameters and flow conditions using a GA-based program
Author/Authors :
Shafaee، نويسنده , , Maziar and Abdehkakha، نويسنده , , Armin and Elkaie، نويسنده , , Abbas، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
8
From page :
137
To page :
144
Abstract :
In this article, the effect of geometrical parameters and flow conditions on the performance of a swirl atomizer is studied. A dimensional analysis and experimental investigations are utilized to define significant terms. The PDA system used for the measurements was able to supply information about the size, concentration and particle velocity at each measurement location. The orifice diameter, the spiral cone angle and also the flow Reynolds number, which is defined based on the injector orifice diameter, play an important role in spray quality, and their significance is summarized in a correlation. In order to achieve the appropriate combination of design variables that satisfy the design constraints, a GA-based program was used in a reverse analysis process. Finally, the advantages of human inspection were employed to provide true best performers from a small group of final answers.
Keywords :
Atomizer , Geometrical parameter , SMD , Spiral injector , Reverse analysis
Journal title :
Aerospace Science and Technology
Serial Year :
2014
Journal title :
Aerospace Science and Technology
Record number :
2231438
Link To Document :
بازگشت