Title of article :
Effects of polishing systems on the surface roughness of tooth-colored materials
Author/Authors :
Erdemir، نويسنده , , Ugur and Yildiz، نويسنده , , Esra and Eren، نويسنده , , Meltem Mert and Ozsoy، نويسنده , , Alev and Topcu، نويسنده , , Fulya Toksoy، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
10
From page :
160
To page :
169
Abstract :
Background/purpose ing systems may affect the surface characteristics of the tooth-colored restorative materials. In this in vitro study, we evaluated the surface roughness of various tooth-colored restorative materials after polishing them with three different polishing systems. als and methods oth-colored restorative materials evaluated were conventional glass–ionomer cement, compomer, microhybrid, and nanofil composite. In total, 112 specimens (10 mm in diameter and 2 mm thick) were prepared in a metal mold using four different tooth-colored restorative materials. After the light curing and setting cycle, seven specimens from each group which received no polishing treatment were used as controls. Specimens were randomly polished with Sof-Lex disks, Poli-pro disks, and the HilusterPlus systems for 30 seconds. The mean surface roughness of each polished specimen was determined with a profilometer and examined using scanning electron microscopy. Data were analyzed using a two-way analysis of variance and Bonferroniʹs post-hoc multiple-comparison test, with a probability level of 0.05. s ing to the two-way analysis of variance, the type of tooth-colored materials, polishing technique, and their interactions were statistically significant (P < 0.001). The smoothest surfaces of all materials were obtained with the Mylar strip. Glass–ionomer cement demonstrated statistically significantly higher Ra values (1.36 ± 0.77) than the other restorative materials tested (P < 0.05). Compomer (0.65 ± 0.28) produced the smoothest surface and did not significantly differ from the microhybrid composite (0.78 ± 0.39; P > 0.05). No significant difference was observed between the microhybrid and nanofil composites (1.08 ± 0.83; P > 0.05). According to the scanning electron microscopy observations, the surface irregularities of the materials were consistent with the surface roughness profilometric findings. sion fectiveness of a polishing system on the surface roughness depends on both the polishing system and restorative material.
Keywords :
Polishing , SEM , tooth-colored restoratives , Surface roughness
Journal title :
Journal of Dental Sciences
Serial Year :
2013
Journal title :
Journal of Dental Sciences
Record number :
2232831
Link To Document :
بازگشت