Author/Authors :
Sadr-Ameli، Mohammadali نويسنده Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Tehran University of Medical Sciences, Tehran, IR Iran , , Mousavi، Hossein نويسنده Department of Chemistry, Payame Noor University, PO Box 19395-3697, Tehran, Iran , , Heidarali، Mona نويسنده Cardiac Electrophysiology Research Center, Rajaie Cardiovascular, Medical and Research Center , , Madaani، Mohsen نويسنده Cardiovascular Intervention Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, IR Iran , , Ghelich، Yones نويسنده Department of Intervention, 502 Military Hospital, Tehran, IR Iran , , Ghadrdoost، Behshid نويسنده Laboratory of Learning and Memory, Research Center and Department of Physiology, School of Medicine, Semnan University of Medical Sciences, Semnan, Iran. ,
Abstract :
The treatment of an occluded saphenous vein graft (SVG) with percutaneous coronary intervention may encounter major adverse cardiac events (MACE). MACE rates have been reduced significantly by using the embolic protection device (EPD). The aim of this study was to clarify the risks and the benefits of embolic protection devices. In a prospective, non-randomized observational study, patients aged 33 to 85 years old who underwent elective percutaneous coronary intervention due to SVG stenosis at our tertiary care center were enrolled between 2009 and 2011. The incidence rates of adverse events, including MACE, were obtained during the patients’ hospitalization and at 30-day and 6-month follow-up. MACE included death, Q-wave and non-Q-wave myocardial infarction, in-stent thrombosis, target lesion revascularization, and target vessel revascularization. From 150 patients enrolled to the study, 128 (85.3%) patients underwent direct stenting and the rest underwent the EPD procedure. In-hospital MACE occurred in 17.2% of the patients in the direct stenting group versus only 9.1% in the EPD group (P = 0.530). MACE incidence was gradually increased at one and 6-month follow-up periods in the direct stenting group (19.5% and 21.9%, respectively), and remained unchanged in the EPD group (9.1% at six-month follow-up). Multivariate logistic regression model showed that the stenting procedure type could not predict early and midterm MACE with the presence of baseline characteristics as cofounders. Despite the considerable lower early and midterm MACE rates, numerically following the EPD procedure compared to direct stenting, the difference in the MACE rates between the two groups was not significant.