Title of article :
Ammonia emissions from naturally ventilated dairy cattle buildings and outdoor concrete yards in Portugal
Author/Authors :
Pereira، نويسنده , , José and Misselbrook، نويسنده , , Tom H. and Chadwick، نويسنده , , David R. and Coutinho، نويسنده , , Joمo and Trindade، نويسنده , , Henrique، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
9
From page :
3413
To page :
3421
Abstract :
There is a lack of information on ammonia (NH3) emissions from cattle housing systems in Mediterranean countries, with most published data deriving from NW Europe. An investigation was carried out in NW Portugal to quantify NH3 emissions for the main types of dairy cattle buildings in Portugal, i.e. naturally ventilated buildings and outdoor concrete yards, and to derive robust emission factors (EFs) for these conditions and compare with EFs used elsewhere in Europe. Measurements were made throughout a 12-month period using the passive flux sampling method in the livestock buildings and the equilibrium concentration technique in outdoor yards. an NH3 emission factor for the whole housing system (buildings + outdoor yards) was 43.7 g NH3–N LU−1 day−1 and for outdoor concrete yards used by dairy cattle was 26.6 g NH3–N LU−1 day−1. Expressing NH3 emission in terms of the quantity of liquid milk produced gave similar values across the three dairy farms studied (with a mean of 2.3 kg N ton-milk−1 produced) and may have advantages when comparing different farming systems. In dairy houses with outdoor yards, NH3 emissions from the yard area contributed to 69–92% of total emissions from this housing system. Emissions were particularly important during spring and summer seasons from outdoor yards with NH3 emitted in this period accounting for about 72% of annual emissions from outdoor yards. Mean NH3 emission factors derived for this freestall housing system and outdoor concrete yards used by dairy cattle in Portugal were higher than those measured in northern Europe. In addition, values of animal N excretion estimated in this study were greater than official National standard values. If these emissions are typical for Portuguese dairy systems, then the current National inventory underestimates emissions from this source in NW of Portugal, because of the use of lower standard values of N excretion by dairy cattle.
Keywords :
Cattle buildings , Emission factors , Natural ventilation , Outdoor yards , Ammonia emissions
Journal title :
Atmospheric Environment
Serial Year :
2010
Journal title :
Atmospheric Environment
Record number :
2236524
Link To Document :
بازگشت