Title of article :
Indoor aldehydes concentration and emission rate of formaldehyde in libraries and private reading rooms
Author/Authors :
Kim، نويسنده , , Jeonghoon and Kim، نويسنده , , Seojin and Lee، نويسنده , , Kiyoung and Yoon، نويسنده , , Dongwon and Lee، نويسنده , , Jiryang and Ju، نويسنده , , DaeYoung، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
6
From page :
1
To page :
6
Abstract :
Aldehydes are of particularly interest due to their potential adverse impact on human health. Formaldehyde is one of the most abundant indoor pollutants. To improve indoor air quality, identifying and removing the major emission sources of formaldehyde would be desirable. The purposes of this study were to determine aldehyde concentrations in libraries and reading rooms and to identify emission sources of formaldehyde in private reading rooms. Indoor aldehyde concentrations were quantified at 66 facilities, including public libraries, childrenʹs libraries, public reading rooms, and private reading rooms, in the Seoul metropolitan area. Emission fluxes of formaldehyde from the surfaces of desks, chairs, floors, walls, and ceilings in 19 private reading rooms were measured using a passive emission colorimetric sensor. Indoor aldehyde (formaldehyde, acetaldehyde, propioaldehyde, benzaldehyde, and hexaldehyde) levels were significantly higher than outdoor levels. Indoor formaldehyde geometric mean concentrations in private reading rooms (119.3 μg m−3) were significantly higher than in public libraries (29.2 μg m−3), childrenʹs libraries (29.3 μg m−3), and public reading rooms (40.8 μg m−3). Indoor formaldehyde levels were associated with relative humidity. In private reading rooms, the emission rates from desks (255.5 ± 214.8 μg h−1) and walls (231.7 ± 192.3 μg h−1) were significantly higher than that from chairs (79.6 ± 88.5 μg h−1). Desks (31%) and walls (29%) were the major emission sources of formaldehyde in 14 facilities in which measurements exceeded the indoor standard of 100 μg m−3. The age of interior materials was a significant factor for indoor formaldehyde emission flux. Controlling the emission rates of desks and walls is recommended to improve formaldehyde concentrations in private reading rooms.
Keywords :
Aldehydes , Emission rate , Private reading rooms , Emission flux , Formaldehyde , Libraries
Journal title :
Atmospheric Environment
Serial Year :
2013
Journal title :
Atmospheric Environment
Record number :
2240857
Link To Document :
بازگشت