Title of article :
Indoor air quality in urban nurseries at Porto city: Particulate matter assessment
Author/Authors :
Branco ، نويسنده , , P.T.B.S. and Alvim-Ferraz، نويسنده , , M.C.M. and Martins، نويسنده , , F.G. and Sousa، نويسنده , , S.I.V.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
11
From page :
133
To page :
143
Abstract :
Indoor air quality in nurseries is an interesting case of study mainly due to childrenʹs high vulnerability to exposure to air pollution (with special attention to younger ones), and because nursery is the public environment where young children spend most of their time. Particulate matter (PM) constitutes one of the air pollutants with greater interest. In fact, it can cause acute effects on childrenʹs health, as well as may contribute to the prevalence of chronic respiratory diseases like asthma. Thus, the main objectives of this study were: i) to evaluate indoor concentrations of particulate matter (PM1, PM2.5, PM10 and PMTotal) on different indoor microenvironments in urban nurseries of Porto city; and ii) to analyse those concentrations according to guidelines and references for indoor air quality and childrenʹs health. Indoor PM measurements were performed in several class and lunch rooms in three nurseries on weekdays and weekends. Outdoor PM10 concentrations were also obtained to determine I/O ratios. PM concentrations were often found high in the studied classrooms, especially for the finer fractions, reaching maxima hourly mean concentrations of 145 μg m−3 for PM1 and 158 μg m−3 PM2.5, being often above the limits recommended by WHO, reaching 80% of exceedances for PM2.5, which is concerning in terms of exposure effects on childrenʹs health. Mean I/O ratios were always above 1 and most times above 2 showing that indoor sources (re-suspension phenomena due to childrenʹs activities, cleaning and cooking) were clearly the main contributors to indoor PM concentrations when compared with the outdoor influence. Though, poor ventilation to outdoors in classrooms affected indoor air quality by increasing the PM accumulation. So, enhancing air renovation rate and performing cleaning activities after the occupancy period could be good practices to reduce PM indoor air concentrations in nurseries and, consequently, to improve childrenʹs health and welfare.
Keywords :
Indoor air , Nursery , Particulate matter , children , exposure
Journal title :
Atmospheric Environment
Serial Year :
2014
Journal title :
Atmospheric Environment
Record number :
2242318
Link To Document :
بازگشت