• Title of article

    Standardless quantification of single fluid inclusions using synchrotron radiation induced X-ray fluorescence

  • Author/Authors

    Jean Cauzid ، نويسنده , , J. and Philippot، نويسنده , , P. and Somogyi، نويسنده , , A. and Ménez، نويسنده , , B. and Simionovici، نويسنده , , A. and Bleuet، نويسنده , , P.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    19
  • From page
    165
  • To page
    183
  • Abstract
    Fluid inclusions are studied using synchrotron radiation induced μ-X-ray fluorescence (μ-SR-XRF). We analyse inclusions from the Brusson gold deposit, Italy. Several two-phase (liquid plus gas) inclusions of a single generation are used to compare a new standardless quantification procedure to previously published internal and external standardisation procedures. The three procedures are based on an infinite homogeneous plane layer and the calculations are performed with a non-iterative fundamental parameter method. Results show a good agreement between the average of the calculated concentrations obtained with the three procedures and the corresponding crush-leach analysis. Cl, K, Ca, Fe, Cu, Zn and As crush-leach concentrations are within error bars of the μ-SR-XRF concentration estimates. Br crush-leach content is above μ-SR-XRF estimates. Ti, Cr, Mn, Ni and Pb were detected with μ-SR-XRF technique only. These elements show different concentrations from one inclusion to another, suggesting heterogeneous trapping of tiny, infra-microscopic solid phases. The good correspondence between the results obtained using the three calibration procedures show that accurate standardless quantitative analysis of individual fluid inclusions is achievable. Statistical error calculation of the three procedures shows that the standardless quantification method yields more accurate results than the internal or external standard procedures. Uncertainties on inclusion depths strongly affect calculated light element concentrations (Cl to Ca), whereas Mn and heavier elements concentration estimates are more sensitive to errors on fluid inclusion thickness. Uncertainties of ± 1 μm or less on fluid inclusion thickness and depth yield statistical errors of ∼ 50% on Cl concentration estimates and lower than 20% on transition metals. This new standardless-μ-SR-XRF based quantification procedure is more precise than the previously established ones and is efficiently applied to multielementary analysis (Cl to Pb) of diluted individual fluid inclusions.
  • Keywords
    Synchrotron radiation , Quantitative analysis , fluid inclusion , X-ray fluorescence
  • Journal title
    Chemical Geology
  • Serial Year
    2006
  • Journal title
    Chemical Geology
  • Record number

    2257953