Title of article
Geometric classification of open-cell metal foams using X-ray micro-computed tomography
Author/Authors
Bock، نويسنده , , Jessica and Jacobi، نويسنده , , Anthony M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
9
From page
35
To page
43
Abstract
The geometry of foams has long been an area of interest, and a number of idealized geometric descriptions have been proposed. In order to acquire detailed, quantitative, geometric data for aluminum open-cell metal foams, X-ray μCT is employed. The X-ray μCT images are analyzed using specialized software, FoamView®, from which geometric information including strut length and pore shapes are extracted. The X-ray μCT analysis allows comparison of the ideal geometric models to the actual geometric characteristics of the metal foam samples. The results reveal a high variability in ligament length, as well as features supporting the ideal geometry known as the Weaire–Phelan unit cell. The geometric findings provide information useful for improving current models of open-cell metal foam. Applications can range from predicting heat transfer or load failure to predicting liquid retention.
Keywords
Metal , Open-cell , Foam , Geometry , tomography , Kelvin
Journal title
Materials Characterization
Serial Year
2013
Journal title
Materials Characterization
Record number
2268674