• Title of article

    Achieving high accuracy and high removal rate in micro-EDM by electrostatic induction feeding method

  • Author/Authors

    Koyano، نويسنده , , T. and Kunieda، نويسنده , , M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    4
  • From page
    219
  • To page
    222
  • Abstract
    With conventional relaxation pulse generators used in micro-electrical discharge machining, due to the difficulty in keeping the minimum necessary discharge interval between pulse discharges, localized discharge and abnormal arc occur frequently. In contrast, with the newly developed electrostatic induction feeding method, only a single discharge occurs for each cycle of the periodic pulse voltage. As this realizes sufficient cooling of the discharge gap between pulses, thermal stress on the machined surface is less and duty factors can be increased, resulting in higher accuracy and machining speed compared to the relaxation pulse generator.
  • Keywords
    Micromachining , Electrical discharge machining , Pulse Generator
  • Journal title
    CIRP Annals - Manufacturing Technology
  • Serial Year
    2010
  • Journal title
    CIRP Annals - Manufacturing Technology
  • Record number

    2268918