Title of article :
Accuracy of industrial computed tomography measurements: Experimental results from an international comparison
Author/Authors :
Carmignato، نويسنده , , Simone، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
4
From page :
491
To page :
494
Abstract :
X-ray computed tomography (CT) is increasingly used in industry for dimensional quality control purposes. However, due to numerous and complex error sources and to the current lack of standardization, industrial users are facing difficulties in the evaluation of CT measurements uncertainty and metrological performance of CT systems. This paper analyses the state of the art in industrial CT metrology, with focus on accuracy and traceability issues, by examining specific results obtained from the first international intercomparison of CT systems for dimensional metrology. The intercomparison involved 15 CT systems operated by expert users in Europe, America and Asia.
Keywords :
Measurement , computed tomography , accuracy
Journal title :
CIRP Annals - Manufacturing Technology
Serial Year :
2012
Journal title :
CIRP Annals - Manufacturing Technology
Record number :