Title of article :
Apex water injection for improved hydrocyclone classification efficiency
Author/Authors :
Honaker، نويسنده , , R.Q. and Ozsever، نويسنده , , A.V. and Singh، نويسنده , , N. and Parekh، نويسنده , , B.K.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
13
From page :
1445
To page :
1457
Abstract :
Classifying cyclones are a widely used device for achieving ultrafine particle size separations in industrial applications. However, inherent deficiencies include particle density effects in multi-component suspensions and ultrafine particle short-circuiting to the underflow stream due to hydraulic entrainment. A detailed in-plant test program has been conducted to evaluate the benefits of tangential water injection into the apex portion of a classification cyclone for the removal or minimization of the ultrafine by-pass. Based on models developed using the test results, ultrafine bypass can be reduced by 50% or more while maintaining the same corrected d50 value through complex manipulation of operating and geometric parameters. In a subsequent test, the by-pass was reduced from 15% to about 7% while maintaining a d50(c) value of 26 microns. However, the magnitude of the benefit in by-pass reduction is subject to the geometric parameters of the conventional classifying cyclone.
Keywords :
MODELING , Coal , hydrocyclones , Fine particle processing , Classification