Title of article :
Improvements in the control of the injection system of copper concentrate in Teniente converters
Author/Authors :
Bergh، نويسنده , , L.G. and Chacana، نويسنده , , P. and Achurra، نويسنده , , G. and Delgado، نويسنده , , P.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
A study to develop a fault diagnosis system in the pneumatic injection of copper concentrate into a Teniente Converter at Caletones Smelter, Chile, is presented. The availability of the injection system must be improved at least in 2% to satisfy the actual production demands. The most frequent operating failures were pump pressurisation and pump overcharge. However, most of the problems were due to disturbances propagation either from the reactor or silo operation. A preliminary diagnosis of the whole system was made in terms of identifying the main constraints to develop and implement a supervisory system. This system must coordinate the local control loops, avoid the main operating problems and provide guidance to operators to handle specific situations, in order to increase the availability of the injection system and to improve the concentrate tonnage control.
Keywords :
expert systems , Process control , sulphide ores , Pyrometallurgy , Process optimisation