Title of article
Electrocoagulation as a remediation tool for wastewaters containing arsenic
Author/Authors
Hansen، نويسنده , , Henrik K. and Nٌْez، نويسنده , , Patricio and Grandon، نويسنده , , Rodrigo، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
4
From page
521
To page
524
Abstract
This work shows results of electrocoagulation of solutions containing arsenic. The continuous flow treatment consisted of an electrocoagulation reactor with two parallel iron plates and a sedimentation basin.
sults showed that the electrocoagulation process of a 100 mg/L As(V) solution could decrease the arsenic concentration to less than 2 mg/L in the effluent with a current density of 1.2 A/dm2 and a residence time of around 9 min. Liquid flow was 3 L/h, and the DC current was reversed each 2 min.
sing the current density from 0.8 to 1.2 A/dm2, the Fe3+ and OH− dosages increase too, and thereby favouring the As removal. On the other hand, it seems that increasing the current density beyond a maximum value, the electrocoagulation process would not improve further. This could probably be explained by passivation of the anode.
Keywords
Oxidation , Reclamation , Flocculation , Environmental , Waste processing