• Title of article

    Performance of a deoiling hydrocyclone during variable flow rates

  • Author/Authors

    Husveg، نويسنده , , Trygve and Rambeau، نويسنده , , Odile and Drengstig، نويسنده , , Tormod and Bilstad، نويسنده , , Torleiv، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    12
  • From page
    368
  • To page
    379
  • Abstract
    Hydrocyclones are state of the art technology for treating produced water offshore. In the acceleration field inside the hydrocyclone oil migrates to the cyclone centre as water is forced to the wall. Separation is depending on the characteristic two-fold vortex flow structure featuring hydrocyclones. Deoiling hydrocyclones do not always meet water quality requirements, however. This paper, describes experimental investigations and hydrocyclone efficiency during transient flow rates. A laboratory test rig exposed a hydrocyclone to severe transient flow rates. Efficiency disturbances may be detected by increased oil-in-underflow, which again is associated with vortex disturbances and plausible vortex breakdown. Experiments led to no such dramatic disturbances. However, separation effects traceable to a limited influence on the flow split were realized. This investigation emphasizes the importance of adequate hydrocyclone operational control. Based on experimental results it is concluded that hydrocyclone efficiency is unaffected by transient flow rates provided the hydrocyclone performance criteria are fulfilled.
  • Keywords
    Water quality , Process control , hydrocyclones , Process optimisation , Deoiling