Title of article
Hydrodynamic and metallurgical characteristics of industrial and pilot columns in rougher circuit
Author/Authors
E. and Massinaei، نويسنده , , M. and Kolahdoozan، نويسنده , , M. and Noaparast، نويسنده , , M. and Oliazadeh، نويسنده , , M. and Yianatos، نويسنده , , J. and Shamsadini، نويسنده , , R. and Yarahmadi، نويسنده , , M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
4
From page
96
To page
99
Abstract
In this investigation, a pilot-scale flotation column was successfully designed, installed and tested in rougher circuit of the Miduk copper concentrator, Iran. The axial dispersion model was employed in the design procedure. Collection zone rate constant (kc) along with the target recovery of over 75% was used to size the column. The rate constant kc was determined based on a number of pilot and industrial experiments. Performance of the pilot column was compared with existing full-scale Microcel columns in a number of parallel experiments.
Keywords
flotation kinetics , froth flotation , Flotation bubbles , Flotation machines
Journal title
Minerals Engineering
Serial Year
2009
Journal title
Minerals Engineering
Record number
2275391
Link To Document