Title of article
Further study on the ignition delay times of propane–hydrogen–oxygen–argon mixtures: Effect of equivalence ratio
Author/Authors
Tang، نويسنده , , Chenglong and Man، نويسنده , , Xingjia and Wei، نويسنده , , Liangjie and Pan، نويسنده , , Lun and Huang، نويسنده , , Zuohua، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
8
From page
2283
To page
2290
Abstract
Using a shock tube facility, measurements on ignition delay times of propane/hydrogen mixtures (hydrogen fraction XH2 is from 0% to 100%) were conducted at equivalence ratios of 0.5, 1.0 and 2.0. Results show that when XH2 is less than 70%, ignition delay time shows a strong Arrhenius temperature dependence, and the ignition delay time increases with the increase of equivalence ratio. When XH2 is larger than 95%, the ignition delay times do not retain an Arrhenius-like temperature dependence, and the effect of equivalence ratio is very weak when the hydrogen fraction is further increased. Numerical studies were made using two selected kinetic mechanisms and the results show that the predicted ignition delay times give a reasonable agreement with the measurements under all test conditions. Both measurements and predictions show that for mixtures with XH2 less than 70%, the ignition delay time is only moderately decreased with the increase of XH2, indicating that hydrogen addition has a weak effect on the ignition enhancement. Sensitivity analysis reveals the key reactions that control the simulation of ignition delay time. Further investigation of the H-atom consumption is made to interpret the ignition delay time dependence on equivalence ratio and XH2.
Keywords
Ignition delay times , Hydrogen fraction , Shock tube measurement , Chemical kinetic , Equivalence ratio dependence
Journal title
Combustion and Flame
Serial Year
2013
Journal title
Combustion and Flame
Record number
2277048
Link To Document