• Title of article

    Measuring gas dispersion parameters: Selection of sampling points

  • Author/Authors

    Araya، نويسنده , , R. and Maldonado، نويسنده , , M. and Gomez، نويسنده , , C.O. and Finch، نويسنده , , J.A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    6
  • From page
    172
  • To page
    177
  • Abstract
    Bubble surface area flux has proven to be a key operational variable in flotation machines not only for diagnosis but also for optimization purposes. It is calculated as a combination of two gas dispersion properties, superficial gas velocity and bubble Sauter mean diameter. Since gas is not necessarily distributed evenly over the cross sectional area of a cell the sampling point where gas dispersion properties are measured must be carefully selected. This article illustrates that a radial parabolic gas velocity profile exists in mechanical cells, in some cases with significant variation in gas velocity as a function of radial distance from the center. An optimal sampling location for single point gas dispersion measurements in mechanical flotation machines is proposed.
  • Keywords
    Flotation , mechanical cell , Gas dispersion , Superficial gas velocity
  • Journal title
    Minerals Engineering
  • Serial Year
    2014
  • Journal title
    Minerals Engineering
  • Record number