Title of article :
Determination of metronidazole by a flow-injection chemiluminescence method using ZnO-doped carbon quantum dots
Author/Authors :
Yan، نويسنده , , Zheng-yu and Xiao، نويسنده , , An and Lu، نويسنده , , Hua and Liu، نويسنده , , Zhen and Chen، نويسنده , , Jian-qiu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
9
From page :
216
To page :
224
Abstract :
ZnO-doped carbon quantum dots (CQDs) were prepared by the chemical oxidation of activated carbon followed by zinc acetate impregnation and precipitation. The ZnO-doped CQDs had a stable fluorescence and a high fluorescence quantum yield. The fluorescence of the ZnO-doped CQDs can be quenched by reduction with metronidazole, allowing a flow-injection chemiluminescence method to be used to determine the metronidazole content in tablets. Under optimum conditions, there was a good linear relation between the concentration of metronidazole and the intensity of chemiluminiscence. The linear concentration range examined was 7.5 × 10−4−2.5 × 10−8 g/mL with r = 0.9996 and a detection limit of 1.08×10−10 g/mL.
Keywords :
Determination , Metronidazole , Flow-injection chemiluminescence , Carbon quantum dots
Journal title :
New Carbon Materials
Serial Year :
2014
Journal title :
New Carbon Materials
Record number :
2278282
Link To Document :
بازگشت