Title of article :
Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
Author/Authors :
-، - نويسنده Liver and Gastrointestinal Diseases Research Center, Tabriz University of Medical Sciences, Tabriz, Iran|Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran Fazeli-Bakhtiyari, Rana , -، - نويسنده Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran Panahi-Azar, Vahid , -، - نويسنده Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran Sorouraddin, Mohammad Hossein , -، - نويسنده Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran Jouyban, Abolghasem
Issue Information :
فصلنامه با شماره پیاپی 0 سال 2015
Pages :
10
From page :
979
To page :
988
Abstract :
-
Abstract :
Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1.0; concentration of NaCl, 4% (w/v)), resulting in a cloudy solution. After centrifugation (6000 rpm for 6 min), an aliquot (1 µl) of the sedimented organic phase was removed using a 1-µl GC microsyringe and injected into the GC system for analysis. One variable at a time optimization method was used to study various parameters affecting the extraction efficiency of target analyte. Then, the developed method was fully validated for its accuracy, precision, recovery, stability, and robustness. Results: Under the optimum extraction conditions, good linearity range was obtained for the calibration graph, with correlation coefficient higher than 0.998. Limit of detection and lower limit of quantitation were 3.2 and 6 μg/ml, respectively. The relative standard deviations of intra and inter-day analysis of examined compound were less than 11.5%. The relative recoveries were found in the range of 97 to 107.5%. Finally, the validated method was successfully applied to the analysis of VPA in patient sample. Conclusion: The presented method has acceptable levels of precision, accuracy and relative recovery and could be used for therapeutic drug monitoring of VPA in human plasma.
Journal title :
Iranian Journal of Basic Medical Sciences
Serial Year :
2015
Journal title :
Iranian Journal of Basic Medical Sciences
Record number :
2279035