Title of article :
Softening and elution of monomers in ethanol
Author/Authors :
Benetti، نويسنده , , Ana R. and Asmussen، نويسنده , , Erik and Munksgaard، نويسنده , , E. Christian and Dewaele، نويسنده , , Magali and Peutzfeldt، نويسنده , , Anne and Leloup، نويسنده , , Gaëtane and Devaux، نويسنده , , Jacques، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
7
From page :
1007
To page :
1013
Abstract :
Objectives rpose of this study was to investigate the effect of light-curing protocol on softening and elution of monomers in ethanol as measured on a model polymer. It was a further aim to correlate the measured values with previously reported data on degree of conversion and glass transition temperature for the same polymer and curing protocols. s ent light-curing protocols were used in order to investigate the influence of energy density, power density, and mode of cure on the properties of a model polymer. The modes of cure were continuous, pulse-delay, and stepped irradiation of the specimens. Wallace hardness was used to determine the softening of the polymer after storage in ethanol for 24 h. Elution of monomers from the polymer was assessed after 7 days in ethanol by means of high-pressure liquid chromatography (HPLC). Data were submitted to two- and three-way analysis of variance (ANOVA), Newman–Keuls’ multiple comparison test, and linear regression analysis. s density, power density, and mode of cure of the polymer influenced the softening and elution of monomers in ethanol. As energy density increased, softening and elution in ethanol decreased. At same energy density, the influence of power density varied with the mode of cure. When compared to the continuous mode of cure, and at same energy density, pulse-delay irradiation resulted in polymers that in general were more susceptible to softening, but eluted monomers to a lower extent. Less elution was also found with step-cured polymers. Significant, negative correlations were detected between softening and elution in ethanol, respectively, and degree of conversion and between softening and elution in ethanol, respectively, and glass transition temperature. icance lex relationship exists between curing protocol and the properties selected for investigation. The effect of different combinations of exposure periods and power densities are important to understanding how the curing protocol affects the properties of polymer-based materials.
Keywords :
Resin composite , Dental polymers , Degree of conversion , glass transition temperature , Photocuring , High-pressure liquid chromatography , Dental materials , Hardness
Journal title :
Dental Materials
Serial Year :
2009
Journal title :
Dental Materials
Record number :
2317213
Link To Document :
بازگشت