• Title of article

    Translucency, opalescence and light transmission characteristics of light-cured resin composites

  • Author/Authors

    Arimoto، نويسنده , , Ayako and Nakajima، نويسنده , , Masatoshi and Hosaka، نويسنده , , Keiichi and Nishimura، نويسنده , , Kozo and Ikeda، نويسنده , , Masaomi and Foxton، نويسنده , , Richard M. and Tagami، نويسنده , , Junji، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    8
  • From page
    1090
  • To page
    1097
  • Abstract
    Objectives luate the translucency, opalescence and light transmission characteristics of resin composites with different thicknesses. s of three resin composites (Estelite∑, Beautifil II, Clearfil Majesty) of A2 shade were prepared in diameter of 10 mm with various thicknesses (0.5 mm, 1.0 mm and 2.0 mm). Color was measured according to CIELAB color scale on a reflection spectrophotometer and a color haze meter, and translucency parameter (TP) and opalescence parameter (OP) were calculated. Using the distribution graphs of transmitted light intensity on a goniophotometer, diffusion factor (DF) as an indicator for a diffuse transmission property and peak gain (G0) for a straight-line transmission property were calculated. s and G0 values significantly decreased in the order: 0.5 mm > 1.0 mm > 2.0 mm thickness (p < 0.05). The OP value increased as the thickness of resin composite increased from 1.0 mm to 2.0 mm (p < 0.05), while was similar for the 0.5 mm- and 1.0 mm-thick groups. The DF value increased from 0.5 mm to 1.0 mm, but was similar for the 1.0 mm- and 2.0 mm-thick groups. There was a significant correlation between TP and DF (R2 = 0.96, p < 0.001). On the other hand, there was a weak correlation between OP and DF (R2 = 0.21, p < 0.005), however within the values of the 0.5 mm-thick group, OP was highly correlated with DF (R2 = 0.84, p < 0.001). icance 0.5 mm thickness, the translucency (TP) and opalescence (OP) of resin composites had a significant correlation with a diffuse transmission property (DF). When more than 1.0 mm thickness of resin composites, translucency and opalescence were influenced by the thickness, in which translucency significantly decreased and opalescence significantly increased.
  • Keywords
    Resin composite , Thickness , Straight-line transmission , Translucency , Opalescence , Diffuse transmission
  • Journal title
    Dental Materials
  • Serial Year
    2010
  • Journal title
    Dental Materials
  • Record number

    2317557