Title of article :
Study on Anomaly Characteristics of In-Advance DC Detection of Water-Accumulating Gob in Abandoned Mines
Author/Authors :
Han، نويسنده , , Depin and Shi، نويسنده , , Xuefeng and Li، نويسنده , , Dan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
7
From page :
217
To page :
223
Abstract :
According to the principle and grading standards of DC electric in-advance detection, the paper analyzed the geophysical characteristics of gob in abandoned coal mines, summed up the verified characteristics of DC electric anomalies in advanced detection of goaf water. The results showed that water-accumulating gob of abandoned mines is commonly characterized by low resistivity, the anomaly bigger than 2 δ (δ is square deviation) is disastrous anomaly; although the old workings full of water in abandoned mines have low resistivity, the amplitude and anomalies is not the same, there are some differences, the workings not fully filled with water have relatively low resistivity; water-accumulating gob near roof and floor sometimes have abnormal response of low resistivity because of infiltration of fractures. There exists interpretation ambiguity for advanced electric detection.
Keywords :
Accumulated water , Anomaly characteristics , DC electric method , advanced detection , Gob of the old mine
Journal title :
Procedia Earth and Planetary Science
Serial Year :
2011
Journal title :
Procedia Earth and Planetary Science
Record number :
2319932
Link To Document :
بازگشت