Title of article
First and second law analysis of diesel engine powered cogeneration systems
Author/Authors
Aysegul Abusoglu، نويسنده , , Aysegul and Kanoglu، نويسنده , , Mehmet، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
6
From page
2026
To page
2031
Abstract
In this article, the thermodynamic analysis of the existing diesel engine cogeneration system is performed. All necessary data are obtained from the actual diesel engine cogeneration plant located at Gaziantep, Turkey. The exergy analysis is aimed to evaluate the exergy destruction in each component as well as the exergetic efficiencies. The thermodynamic performance of a 25.32 MW electricity and 8.1 tons/h steam capacity diesel engine cogeneration system at full load conditions is analyzed. The thermal efficiency of the overall plant is found to be 44.2% and the exergetic efficiency is 40.7%. The exergy balance equations developed in this paper may also be utilized in the exergoeconomic analysis to estimate the production costs depending on various input costs in a diesel cogeneration system.
Keywords
Energy , economy , Exergy , Exergoeconomy , Diesel cogeneration
Journal title
Energy Conversion and Management
Serial Year
2008
Journal title
Energy Conversion and Management
Record number
2333993
Link To Document