Title of article
Exergy-based performance analysis for proper O&M decisions in a steam power plant
Author/Authors
Ray، نويسنده , , Tapan K. and Datta، نويسنده , , Amitava and Gupta، نويسنده , , Amitava and Ganguly، نويسنده , , Ranjan، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
12
From page
1333
To page
1344
Abstract
Exergy analysis of a 500 MWe steam turbine cycle of an operating power plant is conducted under the design and off-design conditions with different degrees of superheat and reheat sprays. The analysis shows how a first law-based analysis shows an apparent (false) improvement in a feed water heater under an off-design condition, while the actual performance degradation is reflected through an exergy analysis. The analysis also helps identifying the contribution of individual equipment in the overall increase of exergy destruction under off-design condition. Exergy analysis is also performed using off-line performance guarantee (PG) tests conducted before and after a unit overhauling. Pre-overhauling exergy efficiency figures of the major cycle equipment are compared with their respective design values to assess the need and extent of maintenance work, whereas post-overhaul exergy data is used to quantify the compliance with the guaranteed performance. Results of the study provide a quantifiable basis for formulating exergy–economy driven maintenance scheduling and PG test procedures.
Keywords
Exergy , Steam power plant , Operation and maintenance decisions , Off-line tests
Journal title
Energy Conversion and Management
Serial Year
2010
Journal title
Energy Conversion and Management
Record number
2335127
Link To Document