Title of article
Numerical simulation of vapor flow and pressure drop across the demister of MSF desalination plant
Author/Authors
Janajreh، نويسنده , , I. and Hasania، نويسنده , , Carly A. and Fath، نويسنده , , H.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
8
From page
793
To page
800
Abstract
This paper presents a numerical simulation of the water vapor flow in an MSF flash chamber along with the pressure drop across the demister. The demister is a simple porous blanket of metal wires mesh (usually made of stainless steel wires) which retains liquid droplets entrained by the vapor momentum to enhance the quality of the product water. Two main areas of concern in wire mesh mist eliminators are; (i) the pressure drop and (ii) the mist removal efficiency. The present simulation focuses only on the pressure drop across the demister. The simulation is carried out considering a full scale flashing chamber of a typical operational MSF desalination plant and of a real industrial demister dimensions. The study simulates the demister as porous media flow. It takes into account the vapor velocity, the dimension of the demister, its porosity and wire thickness. The obtained pressure drop was found to be within a reasonable agreement with the published literature data and it follows a trend compatible with Ergun’s equation as well as the empirical correlation of Svendsen.
Keywords
Desalination , Pressure drop , Flashing chamber , CFD
Journal title
Energy Conversion and Management
Serial Year
2013
Journal title
Energy Conversion and Management
Record number
2336518
Link To Document