Title of article :
An investigation of thermo-compressor design by analysis and experiment: Part 1. Validation of the numerical method
Author/Authors :
Sharifi، نويسنده , , Navid and Boroomand، نويسنده , , Masoud، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
11
From page :
217
To page :
227
Abstract :
Thermal Vapor Compressors are the main part of desalination systems and directly influence the overall efficiency of the systems. In order to improve the design of a Thermal Vapor Compressor (TVC), it is necessary to understand the flow field inside such devices. This study will be presented in two separate parts. The main objective of the first part is to prepare and validate a numerical method to investigate the flow pattern within a conventional TVC. Two numerical schemes on the basis of axisymmetric and three dimensional assumptions are implemented to analyze the performance parameters. The results of both models are compared with the experimental measurements obtained from an industrial desalination unit. It is shown that the axisymmetric model is quite capable of producing similar results to three-dimensional model, and both results are in acceptable agreements with the experimental data. Verification of the numerical method enables us to introduce a new design methodology in the second part of this study.
Keywords :
Thermo-compressor , CFD simulation , Supersonic ejector , Numerical Modeling
Journal title :
Energy Conversion and Management
Serial Year :
2013
Journal title :
Energy Conversion and Management
Record number :
2336775
Link To Document :
بازگشت